Scope and Standards

The mechanical code has rules for dryer ducts: smooth metal pipe, a limited length with less allowed for every bend, and an outside hood with a flap but no screen. Many duct runs in older homes break one or more of them. We clean the duct end to end, look at the hose behind the machine and tell you which parts of the run fall short of the rule.

Duct cleared from the machine to the outside hood
Plastic or foil hose swapped for metal where needed
Run length and bends compared with the code
Hood flap freed of lint and nests
Airflow read at the hood after cleaning

Why dryer ducts clog, and the rules behind them

A clothes dryer pushes a steady stream of moist air and fine lint out through its duct for every load. Whatever lint the filter misses rides that air, and it settles wherever the air slows down: at bends, at sagging sections, at joints where a screw pokes into the airway, and at an outside flap that will not swing fully open. The mechanical code and the dryer makers set rules to keep that from happening. The duct should be smooth metal, with joints that point in the direction of flow and are taped rather than screwed. Foil and plastic accordion hose is not allowed where the duct runs inside a wall or ceiling. The total length is capped, and every bend counts against that cap. The duct must end outside the house with a backdraft flap and no screen, since a screen catches lint. Many of the ducts we see in Rosemead break one or more of these rules, usually because they were added to or rerouted during a remodel.

A duct that breaks the rules clogs faster, and a clogged duct changes how the dryer behaves. Loads take longer to dry, the dryer cycles its heater more, the room around it gets warmer, a burnt smell can appear, and lint gathers around the outside flap. In a gas dryer, a blocked duct also means the combustion exhaust has nowhere to go. Lint is very flammable, and a dryer working against a packed duct is running hotter than it was designed to. Many Rosemead houses have the laundry in the garage or in an inside room near the middle of the house, and in the second case the duct often runs through the attic and up to a roof outlet. Those long, climbing runs collect lint faster than a short run through an outside wall, and their roof outlets are often clogged at the top where nobody can see them.

The cleaning visit and the figure

The cleaning covers the whole run, not just the parts within reach. We detach the duct at the machine, send a spinning brush on flexible rods through the full length, and drive the loosened lint out the far end with a strong air flow, catching it so it does not end up on the roof or in the yard. The outlet flap, on the wall or the roof, is freed so it opens fully under the dryer's air and falls closed when the dryer stops. We also look at the short hose behind the machine; if it is foil or plastic, we tell you it should be replaced with a listed metal connector. We look at the joints we can reach for screws inside the airway and for gaps that let lint and moisture into the wall. Before we leave, the dryer is reconnected and run so we can confirm the air is moving freely at the outlet.

Dryer vent cleaning has no fixed rate on our list, since a short run through a garage wall and a long run up through the attic to a roof outlet are very different jobs. When you book, tell us which room the laundry is in and whether the duct ends on a wall or on the roof, and we give you the figure up front. If the visit shows the run itself breaks the rules, for example it is too long for the dryer, has crushed sections or uses foil inside a wall, we write down what we found and what a compliant run would look like, and price that work separately. Landlords and property managers often book dryer vents together with fireplace inspections for the same building, and the property manager page explains how we handle several units in one visit.

How Edgerton Chimney Group Works

Rule Named

Each finding cites the standard behind it

Permit Checked

City requirements settled before booking

Price on Paper

Extra work is written up before it starts

Records Kept

Photos and reports ready for a buyer or insurer

Where we book dryer vent cleaning

Choose a city for the local housing notes, permit desk pointers and ZIP list.

Full city list

Nothing on our list by that name. The city next door may be covered.

Related Work

Chimney Sweep

Flue brushed and vacuumed back to the clean state NFPA 211 asks for, with deposit depth written down before and after.

Details →

Chimney Inspection

An NFPA 211 inspection at the level your situation calls for, written up so an insurer, buyer or city office can follow it.

Details →

Chimney Repair

Repairs scoped against NFPA 211 and the local building code, so the chimney passes its next inspection, not only the next rain.

Details →

Fireplace Inspection

Firebox, hearth extension, damper and mantel spacing measured against the code tables that apply to your fireplace.

Details →

Fireplace Repair

Cracked firebrick, loose panels, failed doors and short hearths put right so the fireplace meets clearance rules again.

Details →

Chimney Level 2 Inspection

The deeper NFPA 211 inspection a sale, a new appliance or storm damage calls for, with video of the inside of the flue.

Details →

Chimney Cap Installation

A cap and spark arrestor screen fitted to the flue, chosen to meet fire code mesh rules and keep rain and animals out.

Details →

Chimney Flashing Repair

Step and counter flashing rebuilt where the roof meets the chimney, with the upper layer cut into a mortar joint as roofing codes describe.

Details →

Chimney Masonry Repair

Open joints, spalled brick and loose courses repaired with a mortar chosen for the brick, so the new work does not crack the old.

Details →

Chimney Rebuilds

A new chimney top built to today's code, with height, flue size and reinforcing worked out before the old brick comes off.

Details →

Fireplace Cleaning

Ash, soot and creosote cleared from the firebox, smoke chamber and doors, with the room left as clean as we found it.

Details →

Gas Fireplace Cleaning

Lint, dust and nests cleared from a gas unit's ports, pilot and vent, then the flame compared with the maker's manual.

Details →

Gas Fireplace Repair

Ignition, valve and flame faults on gas fireplaces traced and repaired with parts the maker lists for that model.

Details →

Fireplace Remodel

A refaced fireplace with mantel height, hearth depth and trim spacing set by the code before any stone or tile is picked.

Details →

Fireplace Inserts

Gas and wood inserts set into an existing firebox with a full height liner, and the permit and clearances handled on paper.

Details →

Pellet Stove Repair

Jammed, shutting down or code throwing pellet stoves repaired with listed parts, and the vent pipe checked for clearance.

Details →

Wood Stove Repair

Gaskets, baffles, glass and stove pipe repaired so a wood stove seals properly and sits a safe distance from walls.

Details →

Gas Logs

Log sets matched to the firebox, the room and the vent type, then installed to meet the damper rule and the maker's limits.

Details →

Chimney Seismic Retrofit

Unreinforced brick chimneys made safer for the next quake with bracing, strapping or a lighter top, chosen after an inspection.

Details →

Chimney Crown Repair

Cracked crowns sealed or recast with an overhang and a gap at the flue tile, as masonry chimney standards describe.

Details →

Chimney Liner Installation

Listed stainless liners sized from the appliance and run the full flue height, with insulation where the listing asks for it.

Details →

Chimney Leak Repair

Leaks traced from the stain inside back to where water enters, then fixed in the order that stops them soonest.

Details →

Chimney Waterproofing

Brick treated with a repellent that lets vapor out, as the last step once every crack and gap above it is closed.

Details →

Chimney Damper Repair

Stuck, rusted or warped dampers repaired, or swapped for a sealing damper mounted on the chimney top and worked by a cable.

Details →

Chimney Chase Cover

Rusted chase tops on factory built chimneys replaced with a stainless or galvanized cover made to the chase's own size.

Details →