Scope and Standards
Most remodels go wrong on distance, not looks: a wooden mantel set too low, a hearth that stops short, or tile trim run onto a factory unit's face where the manual forbids it. We draw the layout first with the code distances marked, then build the new face in tile, stone, plaster or brick. Where the change needs a permit, you know before work starts.
Designing the new face around the clearance rules
People start a fireplace remodel for the looks, and that is the right place to start. The trouble is that a new face can quietly break the rules the old one met. The residential code keeps combustible material, such as a wood mantel, trim or a wood surround, at least 6 inches from the firebox opening. Between 6 and 12 inches out, anything combustible may project only a small fraction of an inch for every inch of distance, which is why a deep mantel shelf has to sit higher above the opening than a slim one. A carved wood mantel that looked fine in a showroom can end up a few inches too low once it is on the wall. We work out the mantel height and the width of any trim from the rule first, then design around it. The same goes for the hearth: if the new floor or the new face changes its depth, we make sure the noncombustible hearth still reaches the distance the code sets for your opening size.
The facing material itself has to suit the job. Stone, tile, plaster and brick are all noncombustible and can sit right up to the opening, but real stone is heavy, and adding several hundred pounds of veneer to an old brick fireplace face can need a ledge or anchors to carry it. Thin stone and porcelain panels give a similar look with far less weight. Factory-built fireplaces are a separate case. Their makers list which facing materials may be used, how close they can come, and whether a mantel is allowed at all, and those limits are tighter than most people expect. On a factory-built unit we read the manual before drawing anything. A television above a fireplace also raises a question, since the wall above the opening gets hot. We can tell you whether the spot you have in mind will stay within the temperatures the television maker allows.
Remodels that change what the fireplace burns
Many Rosemead remodels go further than a new face. Owners decide to stop burning wood and switch to gas logs or a gas insert, or to close the fireplace and fit an electric unit. Each of those choices changes what the rules ask. Gas logs and gas inserts need a gas line to the fireplace with a shutoff valve, and running new gas pipe is work most cities want permitted and inspected. An insert also needs a liner up the chimney and a check that the flue is sound before it goes in, which is a Level 2 inspection under NFPA 211. Closing a fireplace for good means sealing the flue at the top and the damper at the bottom so moisture and animals stay out. We plan these pieces alongside the design, so the fireplace does not end up looking finished while the gas work still waits for the inspector.
A remodel has no fixed price, because the range runs from new tile around a sound opening to a full rebuild of the face with a new hearth and a gas insert. We start with a visit to measure and to look at the fireplace and chimney as they stand, since there is no point refacing a firebox with cracked firebrick or a flue that needs work. From that visit you receive a written scope that names the materials, the measurements the design was worked from, any repair needed first, and the permit question. Where a gas insert is part of the plan, our installed price for an insert in an existing firebox is $2,950 to $5,950, and the scope folds that in. If you are remodeling before a sale, the home sale page explains how a buyer's inspector is likely to read the new work.
How Edgerton Chimney Group Works
Rule Named
Each finding cites the standard behind it
Permit Checked
City requirements settled before booking
Price on Paper
Extra work is written up before it starts
Records Kept
Photos and reports ready for a buyer or insurer
Where we book fireplace remodel
Choose a city for the local housing notes, permit desk pointers and ZIP list.
CA
Fireplace Remodel in Rosemead
Rosemead filled in on old farm land after World War II, and 77% of its homes were built before 1980. Where those postwar houses have a fireplace, the chimney is brick, so we read it against NFPA 211 before any insert or rebuild permit is pulled.
Open this cityCA
Fireplace Remodel in Temple City
Founded by Walter Temple in the 1920s and incorporated in 1960, the city is mostly detached houses, 80% of units. A typical tract chimney carries steel reinforcement that is now decades old, which matters when a rebuild needs a permit and an inspector checks the steel.
Open this cityCA
Fireplace Remodel in Monterey Park
Building here reaches back to the 1910s, and slopes filled with homes after the war; 79% of the housing predates 1980. On a sloped lot, chimney height above the roof is a code question, and a new insert or cap must still clear it.
Open this cityCA
Fireplace Remodel in Montebello
With 84% of homes built before 1980 and 23% before 1950, Montebello's brick chimneys are old enough that NFPA 211 clearances and liner condition decide whether a gas insert can go in, or whether a rebuild permit comes first.
Open this cityCA
Fireplace Remodel in West Covina
West Covina traded orchards for tracts once the war ended, and from the 1970s many houses got factory-built metal fireplaces. Those units are listed systems, so any cap, chase cover or insert has to match the maker's listing, while the older brick stacks follow masonry rules.
Open this cityRelated Work
Chimney Sweep
Flue brushed and vacuumed back to the clean state NFPA 211 asks for, with deposit depth written down before and after.
Details →Chimney Inspection
An NFPA 211 inspection at the level your situation calls for, written up so an insurer, buyer or city office can follow it.
Details →Chimney Repair
Repairs scoped against NFPA 211 and the local building code, so the chimney passes its next inspection, not only the next rain.
Details →Fireplace Inspection
Firebox, hearth extension, damper and mantel spacing measured against the code tables that apply to your fireplace.
Details →Fireplace Repair
Cracked firebrick, loose panels, failed doors and short hearths put right so the fireplace meets clearance rules again.
Details →Chimney Level 2 Inspection
The deeper NFPA 211 inspection a sale, a new appliance or storm damage calls for, with video of the inside of the flue.
Details →Chimney Cap Installation
A cap and spark arrestor screen fitted to the flue, chosen to meet fire code mesh rules and keep rain and animals out.
Details →Chimney Flashing Repair
Step and counter flashing rebuilt where the roof meets the chimney, with the upper layer cut into a mortar joint as roofing codes describe.
Details →Chimney Masonry Repair
Open joints, spalled brick and loose courses repaired with a mortar chosen for the brick, so the new work does not crack the old.
Details →Chimney Rebuilds
A new chimney top built to today's code, with height, flue size and reinforcing worked out before the old brick comes off.
Details →Fireplace Cleaning
Ash, soot and creosote cleared from the firebox, smoke chamber and doors, with the room left as clean as we found it.
Details →Gas Fireplace Cleaning
Lint, dust and nests cleared from a gas unit's ports, pilot and vent, then the flame compared with the maker's manual.
Details →Gas Fireplace Repair
Ignition, valve and flame faults on gas fireplaces traced and repaired with parts the maker lists for that model.
Details →Fireplace Inserts
Gas and wood inserts set into an existing firebox with a full height liner, and the permit and clearances handled on paper.
Details →Pellet Stove Repair
Jammed, shutting down or code throwing pellet stoves repaired with listed parts, and the vent pipe checked for clearance.
Details →Wood Stove Repair
Gaskets, baffles, glass and stove pipe repaired so a wood stove seals properly and sits a safe distance from walls.
Details →Gas Logs
Log sets matched to the firebox, the room and the vent type, then installed to meet the damper rule and the maker's limits.
Details →Chimney Seismic Retrofit
Unreinforced brick chimneys made safer for the next quake with bracing, strapping or a lighter top, chosen after an inspection.
Details →Chimney Crown Repair
Cracked crowns sealed or recast with an overhang and a gap at the flue tile, as masonry chimney standards describe.
Details →Dryer Vent Cleaning
Lint cleared from the whole dryer duct, with the run, the pipe material and the outside hood compared with the mechanical code.
Details →Chimney Liner Installation
Listed stainless liners sized from the appliance and run the full flue height, with insulation where the listing asks for it.
Details →Chimney Leak Repair
Leaks traced from the stain inside back to where water enters, then fixed in the order that stops them soonest.
Details →Chimney Waterproofing
Brick treated with a repellent that lets vapor out, as the last step once every crack and gap above it is closed.
Details →Chimney Damper Repair
Stuck, rusted or warped dampers repaired, or swapped for a sealing damper mounted on the chimney top and worked by a cable.
Details →Chimney Chase Cover
Rusted chase tops on factory built chimneys replaced with a stainless or galvanized cover made to the chase's own size.