The safety items we check in each unit

These come first because they are where a tenant can be hurt.

  • A carbon monoxide alarm present and sounding on test, where the unit has a fireplace or gas appliance.
  • Gas units: pilot and burner lighting cleanly, the valve shutting fully, no gas odor at the controls.
  • Firebox walls free of cracks or open joints that could pass heat to the framing.
  • A hearth that is whole and deep enough to catch a rolling ember.
  • A damper a tenant can actually open, so smoke has somewhere to go.
  • The chimney top: spark screen in place, no nests, nothing blocking the outlet.

What the law and the standards ask of an owner

California law has called for carbon monoxide alarms in single-family houses from 2011 and in other dwelling units from 2013, wherever there is a fuel-burning appliance, a fireplace or an attached garage. A rental owner installs them and repairs them once told they have stopped working. Our record notes which units have a working alarm and which need one.

NFPA 211 asks for chimneys to be inspected every year and cleaned when needed. Across many fireplaces, a yearly visual check of each one is the practical way to meet that, with the camera kept for flues that show a problem. South Coast AQMD Rule 445 also lets the district ban wood fires on poor-air winter days in Rosemead, so a notice to tenants at the start of the season saves calls later.

How a building visit runs

We work through the units in the order you set. Entry is your call: a staff member with keys, a resident at home or a lockbox code. We need a path to each hearth and, for the chimney tops, a way onto the roof.

Afterward you receive one report per fireplace, dated and labeled by unit, plus a one-page building summary listing what needs work. A unit with a hazard is flagged at the top of that summary so it can be handled before anything else.

Per fireplace pricing

Each fireplace is billed separately, so a building's total depends on how many hearths it has.

Safety and visual check, per fireplace (Level 1)
$58
Camera through one flue where a check finds trouble (Level 2)
$415
Sweeping a wood-burning flue, per fireplace
from $445

Repairs found during a building visit are written up unit by unit, with published prices where we have them.

Manager and board questions

How often should a rental fireplace be checked?

NFPA 211 sets a yearly inspection. Many managers also book a unit between tenants, before the next lease begins.

Do gas fireplaces need the same check?

Yes. A gas unit still sends combustion gases up a vent, and a blocked or loose vent is a carbon monoxide risk. The check covers the burner, the pilot, the valve and the vent top.

What does the board receive?

A dated report per fireplace tied to its unit number, and a summary of open items for the whole building. Both suit a maintenance file or an insurer's request for records.

Who pays when one chimney serves two units?

Your governing documents decide that, not us. Our report shows which flue serves which unit and where the problem sits, which is what a board needs in order to decide.

Can tenants keep using a fireplace after the check?

If we find a hazard, the report says to stop using that fireplace until it is fixed. Otherwise normal use continues, apart from no-burn days.